Basic Info.
Model NO.
RH625
IP Rating
IP68
Certification
CE
Customized
Non-Customized
Specification
188g
Trademark
Ronds
Origin
China
HS Code
9031809090
Production Capacity
2000/Month
Product Description
Working Diagram:
The current problem
Condition monitoring of submersible vertical pumps to predict equipment health requires more innovative methods than have historically been available. Historically, vibration measurements for vertical pumps are taken at the motor. At this location, a clear picture of what is occurring at the hydraulic assembly below is rarely accurate.
Some challenges include:
• Damping from the pump foundation
• False readings from excitation of the above ground stationary assembly
• Distance from sources of vibration in submerged locations
A New Solution
Ronds has developed an innovative solution to permit monitoring of the below ground assembly of vertical pumps to provide a more accurate and complete picture of pump health.
Benefits
• Understand risk of operation for different operating conditions; seasonal changes, water level changes, process condition changes, etc.
• Significantly improved warning of problem conditions, resulting in lower cost of repair and better maintenance planning
• More valuable data for diagnosis and remediation of problems
• Ability to detect if stationary assembly mode shape is being excited during operation
• Interface with cloud-based storage and software allows remote access to data
Suggested Applications
• Service water
• Circulating water
• Condensate
• Cooling water
• Dewatering
• Pipeline Booster
The current problem
Condition monitoring of submersible vertical pumps to predict equipment health requires more innovative methods than have historically been available. Historically, vibration measurements for vertical pumps are taken at the motor. At this location, a clear picture of what is occurring at the hydraulic assembly below is rarely accurate.
Some challenges include:
• Damping from the pump foundation
• False readings from excitation of the above ground stationary assembly
• Distance from sources of vibration in submerged locations
A New Solution
Ronds has developed an innovative solution to permit monitoring of the below ground assembly of vertical pumps to provide a more accurate and complete picture of pump health.
Benefits
• Understand risk of operation for different operating conditions; seasonal changes, water level changes, process condition changes, etc.
• Significantly improved warning of problem conditions, resulting in lower cost of repair and better maintenance planning
• More valuable data for diagnosis and remediation of problems
• Ability to detect if stationary assembly mode shape is being excited during operation
• Interface with cloud-based storage and software allows remote access to data
Suggested Applications
• Service water
• Circulating water
• Condensate
• Cooling water
• Dewatering
• Pipeline Booster
Technical Parameters
RH104C sumbersible sensor
Parameter | Index |
Basic parameters | |
Sensitivity | 100mV/g(±10%) |
Range | ±80g peak |
Non-Linearity | ≤1% |
Frequency Response (±10%) | 0.7~ 7000Hz |
Frequency Response (±3 dB) | 0.4~10000Hz |
Frequency Response | About 25kHz |
Transverse Sensitivity | ≤5% |
Electrical character | |
Bias Voltage | 10.5-13.5VDC Typical: 12VDC |
Constant Current | 2-20mA Typical: 4mA |
Excitation Voltage | 18-30VDC Typical: 24VDC |
Settling time | ≤2S |
Electrical noise, equivalent g spectral | 10Hz 14μg/√Hz 100Hz 5μg/√Hz 1000Hz 3μg/√Hz |
Output Impedance | <100Ω |
Grounding | Case isolated, internal shielded |
Structural features | |
Shock Limit | 5000g |
Mounting Thread | M6*1 |
Weight | About 126g(not include cables) |
Dimension | L*W*H:57.5*22.0*25.0(mm) |
Seal Method | Laser Welding |
Protection Grade | IP68 |
Case Material | 316L stainless steel |
Output Connector | Side axit, integrated wire output |
Working Temperature | -55~+125ºC |
Mounting Torque | About 2.7~6.8N*m (M6 thread) |
Temperature measurement (optional) | |
Measuring Range | -40~+120ºC |
Voltage output | 750mV(25ºC) |
Temperature sensitivity | 10mV/ºC |
Explosion proof (optional) | |
Identification | Ex ia IIC T4 Ga |
RH625 Wireless Transmitter
Vibration measurement parameters | |
Vibration Range | ±50g (peak) |
Frequency Response | Piezoelectric 2~20000Hz (±3 dB) |
Available Frequency ranges | 500Hz,1000Hz,2000Hz,5000Hz,10000Hz,20000Hz |
DAQ sample length | 1K,2K,4K,8K,16K,32K,64K,128K |
Temperature measurement parameters | |
Temperature range | -40~+125ºC |
Temperature accuracy | -40~+125ºC (±1ºC) |
Electrical and Structural parameters | |
Power supply | Lithium-thionyl chloride battery (3.6V 19Ah*2) |
Communication Method | ZigBee 2.4GHz IEEE 802.15.4 |
Transmission distance | 500m ( Under ideal conditions) |
Dimensions | 110mm×90mm×48mm |
Environmental parameters | |
Operating Temperature | -40~+70ºC |
IP grade | IP67 |
Explosion-proof grade | ExibIICT4(1,2) |
RH560 Wireless Gateway
RH560 Wireless data collector | |
Input and output | |
Communication with Sensor | 2.4GHz IEEE 802.15.4 |
Indicator LED | Total 3 pieces (working, communication, abnormal status) |
Number of RH505 connecting | 30~60 units according to real application condition |
Electrical and Structure Parameter | |
Power Supply | 220V AC |
Dimension | 203 mm × 82 mm × 260 mm (Length * Width * Height) |
Weight | 3 kg |
Mounting | Hanging or fixation through holder |
Environmental Parameter | |
Working Temperature | -40~70 °C |
IP grade | IP66 |
Software
Ronds Global Market Performance
RONDS
Contact
Kelly Xu
Tel/ +8617756039295