Basic Info.
Product Description
Technical characteristics
Automatic leak detection: inflate the cabin to check if the system remains sealed. If the sealing requirements are met, enter the sterilization process. If the sealing requirements are not met, continue to inflate and seal before leak detection
Cycle until the sealing conditions are met.
Efficient flash evaporation method: A high-precision constant temperature system ensures zero decomposition of hydrogen peroxide during evaporation, and 100% of hydrogen peroxide forms steam.
Quick residue removal: The configured hydrogen peroxide decomposer not only can quickly and thoroughly decompose spatial hydrogen peroxide, but also can decompose surface hydrogen peroxide residues.
Sterilization process recording: Automatically detect sterilization concentration and draw sterilization process curves.
Door interlock function: The equipment cannot open the doors during operation.
Interior surface antibacterial treatment: The interior surface adopts antibacterial treatment, which can achieve sterilization and antibacterial effects, making the interior surface permanently free of microbial habitats.
Compliant with computerized verification software: The system has audit tracking, electronic signature, and data integrity functions.
Bottom mounted features: The bottom mounted transmission cabin has a compact structure, a small footprint, and is easy to operate.
Material | External all 304 stainless steel, internal chamber 316L stainless steel |
Cleanliness level | Class A |
Wind speed | 0.45m/s ± 20% |
Leakage rate | ≤ 0.5% VOL/h (below 100pa) |
Exhaust volume | ≥ 300m ³/ H |
Pressure control range | 100pa~+100pa |
Sterilization efficiency | 6lg |
VHP residual removal efficiency | ≤ 1PPM |
Control method | Manual or automatic |
Noise | ≤ 68dB (A) |
illumination | ≥ 350LUX |
Model/parameter | Overall dimensions (W*D*H)mm | Operating cabin size (W*D*H)mm | Transmission compartment size (W*D*H)mm | Power supply | Air supply | Explain | ||
STI-1200 | 1600*880*2250 | 1195*680*700 | AC220V /3.5KW | ≥0.6Mpa | Single person single cabin | |||
STI-1200/BPB600 | 1600*880*2250 | 1195*680*700 | 600*680*700 | Single person double cabin | ||||
STI-1500D/BPB600 | 2100*1200*2250 | 1495*1195*700 | 600*680*700 | Single person, double cabin, double sided | ||||
STI-1800 | 2200*880*2250 | 1795*680*700 | AC220V /5.5KW | Double person single cabin | ||||
STI-1800/BPB600 | 2200*880*2250 | 1795*680*700 | 600*680*700 | Double person single cabin | ||||
STI-1800/PB600 | 2800*880*2250 | 1795*680*700 | 600*680*700 | Two person, two cabin | ||||
STI-1800D/BPB600 | 2200*1200*2250 | 1795*1195*700 | 600*680*700 | Double person, double cabin, double sided |
Advantage
(1) All work and material handling in the isolator must be isolated and controlled. No person or body part can directly enter the isolator during operation.
(2) All materials entering the isolator must be decontaminated or sterilized, and must enter directly through the past pollution or sterilization system, or through the fast transfer cabin.
(3) Decontamination methods must be repeatable and quantifiable.
There are two simple purposes to use aseptic isolator. One is to protect samples from environmental pollution, which includes pollution from operators and test environment.
The second is to protect operators from the pollution of toxic and harmful substances.
The application of sterile isolator is very wide, especially in the production of sterile prouducts. The application of sterile isolator in the production of sterile products not only ensures the quality of products, but also reduces the cost.