Basic Info.
Product Description
Application of Battery Testing Equipment:
Vibration encountered of the battery during transportation shall not cause leakage, fire or explosion. The electrodynamic vibration test system is a precision test equipment that simulates the actual working environment of a battery.
The vibration test system consists of four parts: vibration test bench, power amplifier, controller and cooling fan.
Standard of Battery Testing Equipment:
IEC 62133-1 Secondary cells and batteries containing alkaline or other non-acid electrolytes -Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 1:Nickel systems clause 7.2.2;
UN38.3 T3:Vibration
Parameter of Battery Testing Equipment:
Electric Vibration Test bench | |
Rated sinusoidal force (peak) | 3000kgf (30kN) |
Rated random force (peak) | 3000kgf (30kN) |
Rated shock force (peak) | 6000kgf (60kN) |
Frequency range | 1~3000 Hz |
Maximum displacement (p-p) | 76mm |
Maximum Acceleration | 980m/s2 (100g) |
Maximum load | 500 kg |
Table diameter | Ф320mm |
Equivalent mass of moving parts | 30kg |
Table screw | 12×M12 |
Dimension L×W×H | 1940×1640×1100mm |
Weight | About 3100kg |
Power Amplifier | |
Amplifier Output | 35KVA |
Output Voltage | 120Vrms |
Signal to Noise Ratio | >65dB |
Power Amplifier Efficiency | >95% |
System Protection | Temperature protection, over-displacement protection, over-voltage protection, over-current protection, under-voltage protection, external protection, logic fault protection |
Dimensions | 580×1020×1800mm |
Weight | 600kg |
Vertical extension table | |
Table Size | 1500mm×1500mm |
Table Weight | 350kg |
Highest frequency | 200Hz |
Material | Aluminium alloy |
Horizontal Slide Table | |
Table Size | 1500mm×1500mm |
Table Weight | 350kg |
Highest frequency | 200Hz |
Material | Aluminium alloy |
Vibration controller | |
Functions Based on Windows 7 operating system | Basic functions: Sine, Random, Random+Sine, Random+Random, Typical Shock, Resonance Search and Dwell, Transient Shock, Shock Response Spectrum. 2 input channels, 1 output channel, 1 COLA output, reserved with the environmental test chamber linkage interface function (digital I / O interface) |
Fan | |
Fan Power | 7.5KW |
Air volume | 0.52M3/s |
Wind Pressure | 5.8Kpa |
Dimensions | 1100*800*1400mm |
Duct length | 4m |
Weight | 140kg |
Accelerometer | |
Frequency Range | 0.3-8000Hz±10% |
Measuring Range | 2000g |
Impact Resistance | 2500g |
Line length | 5m |
Operating Temperature | -40-150ºC |
Weight | 35Gram |
Installation Method | M5 |